25 kW
Gas Generators / 25RZGB
Return to ResultsFeatures
- Kohler Co. provides one-source responsibility for the generating system and accessories.
- The generator set and its components are prototype-tested, factory-built ,and production-tested.
- The 60 Hz generator set offers a UL 2200 listing.
- The generator set accepts rated load in one step.
- The 60 Hz generato set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards.
- A one-year limited warranty covers all systems and components. Two-, five-, and ten-year extended warranties are also available.
Alternator features:
- The unique Fast-Response II excitation system delivers excellent voltage response and short circuit capability using a permanent magnet (PM)-excited alternator.
- The brushless, rotating-field alternator has broad range reconnectability.
- NEMA MG1 ,IEEE, and ANSI standards compliance for temperature rise and motor starting.
- Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds.
- Sustained short-circuit current enabling down stream circuit breakers to trip without collapsing the alternator field.
- Self-ventilated and dripproof construction.
- Vacuum-impregnated windings with fungus-resistant epoxy varnish for dependability and long life.
- Superior voltage waveform from a two-thirds pitch stator and skewed rotor.
- Fast-Response(TM) II brushless alternator with brushless exciter for excellent load response.
Other features:
- Controllers are available for all applications.
- The electronic, isochronous governor incorporates an integrated drive-by-wire throttle body actuator delivering precise frequency regulation.
Specifications
| Prime Ratings: | 23 kW (28 kVa) | |
| Standby Ratings: | 25 kW (31 kVa) | |
| Hertz: | 60 Hz | |
| Alternator Type: | Brushless, Permanent-Magnet | |
| Engine Manufacturer: | General Motors | |
| Engine Model: | Industrial Powertrain 3.0L | |
| Cylinder Arrangement: | 4-Inline | |
| Max Power at Rated RPM: | 35 kWm (47 BHP) | |
| Prime Fuel Consumption at | ||
| 100% load: | 9.6 m3/hr. (339 cfh) | |
| 75% load: | 7.8 m3/hr. (275 cfh) | |
| 50% load: | 6.1 m3/hr. (215 cfh) | |
| 25% load: | 4.6 m3/hr. (162 cfh) | |
| Standby Fuel Consumption at | ||
| 100% load: | 10.4 m3/hr. (367 cfh) | |
| 75% load: | 8.4 m3/hr. (297 cfh) | |
| 50% load: | 6.4 m3/hr. (226 cfh) | |
| 25% load: | 4.8 m3/hr. (170 cfh) | |
| Prime Fuel Consumption at | ||
| 100% load: | 9.6 m3/hr. (339 cfh) | |
| 75% load: | 7.8 m3/hr. (275 cfh) | |
| 50% load: | 6.1 m3/hr. (215 cfh) | |
| 25% load: | 4.6 m3/hr. (162 cfh) | |
| Standby Fuel Consumption at | ||
| 100% load: | 10.4 m3/hr. (367 cfh) | |
| 75% load: | 8.4 m3/hr. (297 cfh) | |
| 50% load: | 6.4 m3/hr. (226 cfh) | |
| 25% load: | 4.8 m3/hr. (170 cfh) | |
Options
Generator Controls
Decision-MakerŪ 550Decision-MakerŪ 3+
Decision-MakerŪ 1
Decision-MakerŪ 3000